Highlights
-
Multi-channel flexible measurementSupports for 2-channel low leakage current input
Supports 12 input channels and 48 output channels -
High voltage, low leakage currentMatrix leakage current: <200 pA @ 2000 V
-
Rapid measurementSwitch matrix current settling time: <1 s
(Time from 1000 V input to current settling below 1 nA) -
High relay contact lifeThe switch life >10⁸ times
-
5MHz BWOptimize the transmission bandwidth of C-V and DMM channels
Up to 5 MHz @ -3 dB -
Supports 2 control methodsRun the upper computer GUI software on the PC
Standard commands SCPI through programmable instruments